Low Leakage 3-Way Valve for Marine Engine Cooling Systems

Near-zero internal leakage. Sub-one-year payback. Fits any existing 3-way valve installation, no drydocking required.

Request a quote

The hidden fuel cost in your cooling circuit

Every vessel with a traditional main engine has a high-temperature (HT) fresh water cooling circuit. During port stays, the main engine is shut down but must be kept warm, typically at around 80°C, so it is ready to start on short notice. A jacket water preheater maintains that temperature while the engine is not running.

What most operators do not account for is what happens at the 3-way valve during those hours at berth. Conventional wax-element thermostatic valves are not designed to fully close. They leak - typically 2% or more of the low-temperature (LT) cooling water continuously bleeds into the HT circuit if they are connected by this valve. That cold water has to be compensated with additional heating requirements by the preheater which in turn requires additional fuel burned in the boiler, every hour the vessel is in port. For vessels with frequent port calls, container feeders, car carriers, bulk carriers on short-sea trades, this is not a small rounding error. It is a persistent, measurable cost that exists on many vessels in service, and one that is rarely addressed.

The Low Leakage 3-Way Valve eliminates it.

How the Low Leakage 3-Way Valve works

The Low Leakage 3-way Valve is a purpose-engineered rotary control valve that replaces the conventional thermostatic 3-way valve in your main engine HT cooling water circuit. It is electrically actuated and controlled by a PID electronic controller with a temperature sensor fitted to the engine jacket water circuit.

During port stay, the valve closes the path to the LT system completely, internal leakage of less than 0.01% (Class IV). The preheater only compensates for actual heat loss from the circuit, not for cold water continuously entering it. During sailing, the valve adjusts automatically to maintain precise jacket water temperature, responding faster and more accurately than  most commercial valves to changes in engine load, ambient conditions, and cooling water temperatures.

The valve can be integrated with the vessel's Computerised Alarm and Monitoring System (CAMS) or operated via a standalone controller supplied as part of the installation.

Where the savings come from

Port stay fuel reduction

The primary saving is straightforward: when the LT path is fully closed, the preheater doesn’tneed to compensate for leakage heat loss. On vessels spending a significant proportion of their operating time in port, this translates directly to measurable reductions in auxiliary boiler fuel consumption. The saving is continuous across every port call and every hour at berth.

Improved jacket water temperature control at sea

Common 3-way valves supplied from shipyards respond slowly to temperature changes and have a fixed response characteristic that cannot be tuned. The Low Leakage 3-Way Valve uses electronic PID control, which reacts faster, holds temperature more precisely, and can be configured to match the specific thermal behaviour of each vessel's cooling system. Tighter temperature control supports optimal engine combustion conditions and reduces thermal cycling stress on the jacket water circuit.

Reduced preheater and boiler maintenance load

Reducing the demand on preheaters and subsequently auxiliary boilers extends their service intervals and reduces wear, a secondary benefit that compounds over the vessel's operational life.

Built for marine duty. Proven in service.

Leakage performance

Electronic PID control

Retrofit compatibility

Maintenance and service life

CII compliance

Plug-and-play retrofit. No drydocking required.